Customization: | Available |
---|---|
After-sales Service: | 1 Year |
Material: | Stainless Steel |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The capacity of the cabin is 60L and 1L, and the number of cabins can be customized (2 to 12 cabins).
The VOC formaldehyde emission test box is suitable for measuring the emission of volatile organic compounds in sample equipmentPlastic surface layer, VOC testing in runways; Testing of formaldehyde VOC emissions from wood products and building decoration materials, and research on pollutant emissions from materials; The purpose of environmental labeling product certification.
Multi cabin combination structure, capable of testing multiple samples simultaneously; Ultra low VOC background concentration control, multi-layer physical and chemical filtration purification; Advanced air sleeve temperature control technology, temperature and humidity adjustment technology, automatic recording of temperature, humidity, pressure, flow rate, etc
ASTMD6007-2 | Standard Test Method for Determining Formaldehyde Concentrations in Air from Wood Products Using a Small-Scale Chamber |
EN717-1 | Wood-based panels- Determination of formaldehyde release- Part 1: Formaldehyde emission by the chamber method |
ISO16000-9 | Indoor air- Part 9: Determination of the emission of volatile organic compounds from building products and furnishing-Emission test chamber method |
DIN EN 16516-2018 | Building products - Evaluation of the release of hazardous substances - Determination of emissions to indoor air |
GB18580-2017 | Formaldehyde emission limit of interior decoration materials wood-based panels and their products |
LY-T1612-2004 | The climate chamber for determination of formaldehyde emission |
GB 18580-2017 | Indoor decorating and refurbishing materials- Limit of formaldehyde emission ofwood-based panels and finishing products |
GB 18584-2011 | Interior Decoration Materials - Limits of Hazardous Substances in Wooden Furniture |
GB 18587-2001 | Interior Decoration Materials-Carpet, Carpet Backing and Carpet Adhesive Hazardous Substance Release Limits |
Studio volume | 60L |
Studio | 300×500×400mm(width x depth x height)×4 |
Exterior | 1.8×0.98×1.75m(width x depth x height) |
Temperature range | 15~70ºC ★Meet the requirements of plastic surface testing(60ºC,5%R.H.) |
Temperature fluctuation | ≤ ±0.5ºC |
Temperature uniformity | ≤±0.5ºC |
Temperature resolution | 0.1ºC |
Temperature control | Indirect temperature control method in constant temperature room |
Humidity range | 3~80 % R.H. ★Meet the requirements of plastic surface testing(60ºC,5%R.H.) |
Humidity fluctuation | ≤ ±2% RH |
Humidity uniformity | ≤ ±2 % RH |
Humidity resolution | 0.1 % RH |
Humidity control | Dry and moisture proportional control method (external) |
Formaldehyde background value | ≤0.006 mg/m3 |
Individual VOC background value | ≤0.002 mg/m3 |
TVOC background value | ≤0.02 mg/m3 |