Customization: | Available |
---|---|
After-sales Service: | Remote Operation, Video Calls, House Calls |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Acceleration Mechanical Impact Testing Equipment Used to measure and determine the impact resistance of products or packaging, to assess the functional reliability and structural integrity of the test product under impact environment
This equipment meets GB/T2423.5 "Basic Environmental Test Procedures for Electrical and Electronic Products Ea: Impact Test Method", GB/T2423.6 "Basic Environmental Test Procedure for Electrical and Electronic Products Ea: Collision Test Method", GJB150.18-2008 "Military Equipment environmental test method: impact test and other relevant test standards for impact test requirements. For the new energy sector, meet GB/T 31467.3-2015.
(1) Windows-based stable control system: fully automatic remote control interface, the operator only needs to input simple values;
(2) Full air pressure drive lift, impact, clean and environmentally friendly, good repeatability and high reliability;Main technical indicators | ||
Rated load (kg) | 50 (including fixtures, test pieces, sensors, etc.) | |
Shock pulse waveform | Half sine wave | |
Pulse form | Free fall | |
Peak acceleration (m/s2) | Half sine: 150 m/s2 to 5000 m/s2 (1g=9.8 m/s2, up to 600g at 3ms) After peak sawtooth wave: 150 m/s2 to 3000 m/s2 Trapezoidal wave: 150 m/s2 to 1000 m/s2 |
|
Pulse duration (ms) | Half sine: 30ms ~ 1ms After peak sawtooth wave: 18ms ~ 3ms Trapezoidal wave: 18ms ~ 6ms Maximum speed change rate: ≥7.4m/sec Lifting height: 1500mm (using hydraulic lifting, designed for international mainstream) |
|
Impact direction | Z axis | |
Continuous impact times | Not less than 3 times | |
Precision requirements | Meet the 6.2.2 tolerance requirements in GJB 150.18A | |
Table size (length × width) | 500mm×500mm | |
Dimensions (length × width × height) | Subject to the real thing | |
Total weight of equipment (kg) | 2500 | |
power supply | 220VAC±10% 50Hz | |
User provides environmental conditions | Temperature (°C) | 0~40 |
Humidity (25 ° C) | <85% | |
Stable gas source (MPa) | ≤0.8MPa | |
Applicable standard | GB2423, GJB150, GB/T 31467.3, IEC68-2-29, etc. |