Customization: | Available |
---|---|
After-sales Service: | 1 Year |
Power Supply: | AC 380V 50Hz |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
GB/T2423.1-2008 Environmental testing of electrical and electronic products Part 2 Test methods Test A Low temperature
GB/T2423.2-2008 Environmental testing of electrical and electronic products Part 2: Test methods Test B: High temperature
GB/T2423.22-2012 Environmental Test Part 2: Test Method Test N: Temperature Change
GJB150.5-2009 Environmental test methods for mil equipment - Temperature shock test
GJB150.5A-2009 mil equipment laboratory environmental test methods Part 5: Temperature shock test
GJB360B-2009 Test methods for electronic and electrical components
GB/T2423.1-2008/IEC6008-2-1-2007 Environmental testing of electrical and electronic products Part 2: Test methods Test A: Low temperature
GB/T2423.2-2008 Environmental testing of electrical and electronic products Part 2: Test methods Test B: High temperature
GB/T10589-2008 Technical conditions for low temperature test chamber
GB/T11158-2008 High temperature test chamber technical conditions
IEC68-2-14 Test method N: Temperature change
Main Specifications | ||
Cabinet | ||
Studio size | Approximately W 1000 × H 1000 × D 1000 (mm) (mm)(W width × H height × D depth) |
|
Dimensions | Approximately 1950×2350×2250(mm), subject to the actual product | |
Volume | 1000L; | |
Noise | Within 75dB (measured 1 meter from the front of the machine and 1.2 meters from the ground) | |
Temperature | ||
High temperature zone | Temperature range | RTºC~+200ºC |
Heating time | RT~+200ºC: about 30min | |
Low temperature zone | Temperature range | RT~-55ºC |
Cooling time | RT~-55ºC: about 55min | |
Studio | Temperature shock range | -65ºC~+150ºC |
Temperature fluctuation | ≤±0.5 | |
Temperature deviation | ≤±2ºC | |
Temperature uniformity | ≤2ºC | |
Temperature conversion time | ≤10s(Damper opening time) | |
Temperature recovery time | ≤4min | |
Operation mode | There are two high and low temperature impact modes and high and low temperature + room temperature impact modes, which can be set by the human-machine interface. | |
High and low temperature shock mode | 150ºC(30min)-NC--40ºC(30min) | |
High and low temperature + room temperature impact mode | 150ºC(30min)-room temperature--40ºC(30min) | |
Power | High greenhouse power: 9KW Low temperature greenhouse power: 9KW Other power about: 2KW Maximum power about: 20KW Operating power approximately: 12KW |
|
Voltage | Power requirements: 380V 50HZ three-phase five-wire system plus ground wire Power: 20KW current 40A |
|
Condensation method | Water cooling | |
Gross weight | 550KG |