Customization: | Available |
---|---|
After-sales Service: | 1 Year |
Power Supply: | 380V |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Meets the requirements of GB/18801-2015 "Air Purifier", evaluates and measures the air purifier's detection of particulate matter and gaseous pollutants clean air volume and cumulative purification volume (CCM), and can be used for small (vehicle) purifiers to clean air Quantity (CADR) test
GB/18801-2015 "Air Purifier"
GB/18803-2002 "Indoor Air Quality Standards"
Test chamber volume | 3 cubic meter |
Inside size of test chamber | 1400* 1400*1500mm(LW*H), 0.1m3 deviation allowed |
Door | 1400*1500mm(W*H) single opening fully sealed type |
Temperature control method | Temperature and humidity control BTHC method (balanced temperature and humidity control method) |
Performance | |
Temperature Range | 15~40°C |
Temperature Volatility | ≤±0.5°C |
Temperature Evenness | ≤2°C |
Humidity Range | 40~80%RH |
Humidity Volatility | ≤±3%RH |
Humidity Evenness | ≤5%RH |
External temperature and humidity control: In order to ensure that the test chamber can meet the temperature and humidity conditions specified in GB/T18801-2015, the outside of the test needs to provide a temperature source environment of 25°C+2°, 50%+10% | |
Material (glass) | |
Frame | 1.2mm thick, 304 stainless steel, with casters, can be easily moved as a whole |
Wall | 10mm thick tempered glass |
Floor/Roof | 3.0mm thick 304 stainless steel plate |
Material (stainless steel) | |
Frame | 2.0mm thick, 304 stainless steel, casters installed, can be easily moved as a whole |
Wall | 2.0mm thick 304 stainless steel plate |
Floor | 3.0mm thick 304 stainless steel plate |
Material(Stainless steel + insulation) | |
Extemnal | Prefabricated warehouse board, cold rolled steel sheet 0.8mm, surface electrostatic spraying, white |
Intemnal | SUS304 stainless steel 1.0mm (8k mirror surface), bottom plate stainless steel 3.0mm |
Adiabatic | High-density polyurethane composite material, thickness 100mm |
Sealing material | Silicone (medical grade) or polytetrafluoroethylene |
Stirring fan | 600m diameter, three-leaf metal blade |
Sampling port | A total of 3, located on the left wall of the main entrance with ball valve control, with hose |
Illumination | 1 LED fluorescent lamp |
Clean system (internal purification system) | Medium eficiency filter, high efficiency filter, activated carbon filter |
Test Bench | Stainless steel test bench 300* 500*400mm (L*W*H) |
Glove box device | Installed on the hatch, about 70cm in length |
Background concentration | Formaldehyde: s0.01mg/m3 Toluene: 0.02mg/m3 (the background concentration of the air outside the environmental chamber complies with GB/T18883 regulations) The background concentration of particles with a particle size above 0.3um is <1000 particles/L |
Air tightness | The number of air changes is not more than 0.05h" |
1.Q :How to provide after-sales service?