After-sales Service: | 1 Year |
---|---|
Power Supply: | AC 380V |
Certification: | CE, TUV, ISO |
Warranty: | 1 Year |
Test Chamber Volume: | 3m³ |
Inside Size of Test Chamber: | 1400* 1400*1500mm(Lw*H), 0.1m3 Deviation Allowed |
Customization: |
---|
Suppliers with verified business licenses
GB/18801-2015 Air purifier
GB/18803-2002 Indoor air quality standard
GB50243-2002 Construction acceptance specification for ventilation and air conditioning projects
GB7251-1997 Low-voltage complete switchgear and control equipment
Test chamber volume | 3m³ |
Inside size of test chamber | 1400* 1400*1500mm(LW*H), 0.1m3 deviation allowed |
Door | 1400*1500mm(W*H) single opening fully sealed type |
Temperature control method | Temperature and humidity control BTHC method (balanced temperature and humidity control method) |
Performance | |
Temperature Range | 15~40°C |
Temperature Volatility | ≤±0.5°C |
Temperature Evenness | ≤2°C |
Humidity Range | 40~80%RH |
Humidity Volatility | ≤±3%RH |
Humidity Evenness | ≤5%RH |
External temperature and humidity control: In order to ensure that the test chamber can meet the temperature and humidity conditions specified in GB/T18801-2015, the outside of the test needs to provide a temperature source environment of 25°C+2°, 50%+10% | |
Material (glass) | |
Frame | 1.2mm thick, 304 stainless steel, with casters, can be easily moved as a whole |
Wall | 10mm thick tempered glass |
Floor/Roof | 3.0mm thick 304 stainless steel plate |
Material (stainless steel) | |
Frame | 2.0mm thick, 304 stainless steel, casters installed, can be easily moved as a whole |
Wall | 2.0mm thick 304 stainless steel plate |
Floor | 3.0mm thick 304 stainless steel plate |
Material(Stainless steel + insulation) | |
Extemnal | Prefabricated warehouse board, cold rolled steel sheet 0.8mm, surface electrostatic spraying, white |
Intemnal | SUS304 stainless steel 1.0mm (8k mirror surface), bottom plate stainless steel 3.0mm |
Adiabatic | High-density polyurethane composite material, thickness 100mm |
Sealing material | Silicone (medical grade) or polytetrafluoroethylene |
Stirring fan | 600m diameter, three-leaf metal blade |
Sampling port | A total of 3, located on the left wall of the main entrance with ball valve control, with hose |
Illumination | 1 LED fluorescent lamp |
Clean system (internal purification system) | Medium eficiency filter, high efficiency filter, activated carbon filter |
Test Bench | Stainless steel test bench 300* 500*400mm (L*W*H) |
Glove box device | Installed on the hatch, about 70cm in length |
Background concentration | Formaldehyde: s0.01mg/m3 Toluene: 0.02mg/m3 (the background concentration of the air outside the environmental chamber complies with GB/T18883 regulations) The background concentration of particles with a particle size above 0.3um is <1000 particles/L |
Air tightness | The number of air changes is not more than 0.05h" |