Vertical Thermal Shock Test Chamber

After-sales Service: 1 Year
Power Supply: AC 380V
Certification: CE, TUV, ISO
Warranty: 1 Year
Temperature Shock Range: -65ºC~+150ºC
Temperature Fluctuation: ≤±0.5
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (21)
  • Overview
  • Application
  • Meet the standards
  • Features
  • Machine structure
  • Product Parameters
  • Company Profile
Overview

Basic Info.

Model NO.
HYTS-100C
Temperature Deviation
≤±2ºC
Temperature Uniformity
≤2ºC
Temperature Conversion Time
≤10s (Damper Opening Time)
Temperature Recovery Time
≤4min
Transport Package
Standard Export Wooden Box
Specification
Customized
Trademark
HUANYI
Origin
China
HS Code
8419899090
Production Capacity
10000pieces/Year

Product Description

Application

Three zones thermal shock chambers can be used to test the tolerance of products in the continuously changing temperature environment between two extreme temperatures. Through thermal shock testing, we can understand the failure of the product due to repeated changes in temperature.

Three zones thermal shock chambers are mainly composed of independent product testing area, high temperature heat storage area and low temperature storage area. In addition, there are auxiliary refrigeration units and electrical control cabinets.

Meet the standards

Three Zones Thermal Shock Chambers Test Standards
GB/T 2423.1-2008 (IEC68-2-1) Test Ab: low temperature test method.

GB/T 2423.2-2008 (IEC68-2-2) Test Bb: High temperature test method.

GJB360.8-2009 (MIL-STD.202F) High temperature life test.

GJBl50.3-2009 (MIL-STD-810D) High temperature test method.

GJBl50.4-2009 (MIL-STD-810D) Low temperature test method.

Features

1.Intelligent, energy-saving refrigeration design: Independent cold-side and hot-side PID regulation to reduce energy waste.
2.Prevent condensation and frost: High and low temperature resistant silicone rubber seal and door frame anti-condensation electric heating device.
3.Insulation layer material:Low -temperature zone: Rigid polyurethane foam insulation layer, flame retardant B2.High temperature zone: Glass fiber cotton insulation layer, flame retardant A1.
4.Solid and durable structure: High quality cold-rolled steel plate external chamber, the surface static powder paint. SUS304 stainless steel plate inner chamber.

Machine structure

The pre-cooling area, preheating area and test area are independent. The three boxes can be switched through the air door without moving the test product. When the room temperature is affected, the ambient temperature is introduced into the test space through the blower to eliminate the heat or cold in the test space. At the same time, The damper of the high and low temperature tanks is closed; when the low temperature is hit, the dampers of the high temperature and normal temperature tanks are closed, and the low temperature tank is connected to the test chamber, and the pre-stored cold energy is instantly introduced into the test chamber; when the high temperature is hit, the dampers of the low temperature and normal temperature tanks are closed, and the high temperature tank is connected to the test chamber. , instantly introducing the pre-stored heat into the test chamber. This achieves the purpose of rapid temperature changes.

Product Parameters

Main Specifications
Cabinet:
Studio size ApproximatelyW 500 × H 450 × D 400 (mm) (W width × H height × D depth)
Dimensions Approximately 1450×1800×1650(mm), subject to the actual object
Volume 100L;
Noise Within 75dB (measured 1 meter from the front of the machine and 1.2 meters from the ground)
Temperature:
High temperature zone
 
Temperature range RTºC~+200ºC
Heating time RT~+200ºC: about 30min
Low temperature zone
 
Temperature range RT~-55ºC
Cooling time RT~-55ºC: about55min
Studio




 
Temperature shock range -65ºC~+150ºC
Temperature fluctuation ≤±0.5
Temperature deviation ≤±2ºC
Temperature uniformity ≤2ºC
Temperature conversion time ≤10s(Damper opening time)
Temperature recovery time ≤4min
Operation mode There are two high and low temperature impact modes and high and low temperature + room temperature impact modes, which can be set by the human-machine interface.
High and low temperature shock mode 150ºC(30min)-NC--40ºC(30min)
High and low temperature + room temperature impact mode 150ºC(30min)-room temperature--40ºC(30min)
Power High greenhouse power: 9KW
Low temperature greenhouse power: 9KW
Other power about: 2KW
Maximum power about: 20KW
Operating power approximately: 12KW
Voltage Power requirements: 380V 50HZ three-phase five-wire system plus ground wire             
Power: 20KW    Current 40A
Condensation method Water cooling

Vertical Thermal Shock Test ChamberVertical Thermal Shock Test ChamberVertical Thermal Shock Test ChamberVertical Thermal Shock Test ChamberVertical Thermal Shock Test ChamberVertical Thermal Shock Test ChamberVertical Thermal Shock Test Chamber

Company Profile

Vertical Thermal Shock Test ChamberVertical Thermal Shock Test ChamberVertical Thermal Shock Test ChamberVertical Thermal Shock Test ChamberVertical Thermal Shock Test ChamberVertical Thermal Shock Test ChamberVertical Thermal Shock Test ChamberVertical Thermal Shock Test ChamberVertical Thermal Shock Test Chamber

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
41
Year of Establishment
2007-03-20