• 3370L Constant Temperature and Humidity Test Chamber Electrical Safety Tester Environmental Climatic Testing Equipment /Test Chamber
  • 3370L Constant Temperature and Humidity Test Chamber Electrical Safety Tester Environmental Climatic Testing Equipment /Test Chamber
  • 3370L Constant Temperature and Humidity Test Chamber Electrical Safety Tester Environmental Climatic Testing Equipment /Test Chamber
  • 3370L Constant Temperature and Humidity Test Chamber Electrical Safety Tester Environmental Climatic Testing Equipment /Test Chamber
  • 3370L Constant Temperature and Humidity Test Chamber Electrical Safety Tester Environmental Climatic Testing Equipment /Test Chamber
  • 3370L Constant Temperature and Humidity Test Chamber Electrical Safety Tester Environmental Climatic Testing Equipment /Test Chamber

3370L Constant Temperature and Humidity Test Chamber Electrical Safety Tester Environmental Climatic Testing Equipment /Test Chamber

After-sales Service: 1 Year
Power Supply: 220V/380V
Certification: CE, TUV, ISO
Warranty: 1 Year
Outer Box Size (Wxhxd) Cm: Customized Size
Temperature Range: -20~150ºC
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (21)
  • Overview
  • Product Description
  • Fulfill the standard
  • Product Parameters
  • Detailed Photos
  • Company Information
Overview

Basic Info.

Model NO.
HYH-3370
Humidity Range
20%-98%Rh
Temperature and Humidity Fluctuation
±0. 5ºC / ±2. 5%Rh
Cooling Rate
About 1ºC/Min (Average Non-Linear No-Load)
Heating Rate
About 3ºC/Min (Average Non-Linear No-Load)
Transport Package
Wooden Package
Specification
Customized size according to actual customer needs
Trademark
HUANYI
Origin
China
HS Code
9013809000
Production Capacity
10000/Year

Product Description

Product Description

Constant temperature and humidity test chamber is also called constant temperature and humidity testing machine, constant temperature and humidity test chamber, programmable heat and humidity alternating test chamber, constant temperature machine or constant temperature and humidity chamber. This equipment is used to test the performance of products at constant humidity and temperature under simulated temperature and humidity conditions of the natural environment to evaluate product performance, stability and durability. It has a wide range of applications and can test various materials, electronic components, auto parts, food, drugs, etc.

1. What are the five major systems of the constant temperature and humidity test chamber? It is composed of control system, refrigeration system, heating system, humidity system and air circulation system. The above systems belong to two major aspects: electrical and mechanical refrigeration.

1. Control system:

The control system is the core of the constant temperature and humidity test chamber, which determines important indicators such as the heating and cooling rate and accuracy of the constant temperature and humidity chamber. The controllers of existing constant temperature and humidity test chambers mostly use PID control, and a few use a control method that combines PID and fuzzy control.

2. Refrigeration system:

The refrigeration system is one of the important components of the constant temperature and humidity test chamber. Generally speaking, the refrigeration method is mainly completed by mechanical refrigeration. Mechanical refrigeration uses vapor compression refrigeration. They are mainly composed of a compressor, a condenser, a throttling mechanism and an evaporator. The refrigeration method of a constant temperature and humidity box There are two types, namely single-stage refrigeration and double-stage refrigeration. For temperatures below -40°C, double-stage refrigeration is generally better.

3. Heating system:

The heating system of the constant temperature and humidity test chamber is mainly composed of high-power resistance wires, which is simpler than the refrigeration system. Since the chassis requires a high heating rate, the heating system power is relatively large, and the bottom plate of the test chamber is also equipped with a heater.

4. Humidity system:

The humidity system is divided into two subsystems: humidification and dehumidification.

The humidification method generally adopts the steam humidification method, that is, low-pressure steam is directly injected into the test space for humidification. This humidification method is fast and has sensitive humidification control. It is easy to achieve forced humidification especially during cooling.

There are two dehumidification methods: mechanical refrigeration dehumidification and dryer dehumidification.

(1) The dehumidification principle of mechanical refrigeration dehumidification is to cool the air below the dew point temperature, condense and precipitate the moisture that exceeds the saturated humidity, and reduce the humidity.

(2) Dryer dehumidification uses an air pump to extract the air from the test chamber, inject dry air, and at the same time send the moisture to a recyclable dryer for drying. After drying, it is sent to the test chamber for repeated cycle dehumidification.

(3) At present, most comprehensive test chambers use the former dehumidification method. The latter dehumidification method can make the dew point temperature lower than 0°C and is suitable for occasions with special requirements, but the cost is higher.

5. Air circulation system:

The air circulation system of a constant temperature and humidity test chamber generally consists of a centrifugal fan and a motor that drives it. It provides air circulation in the constant temperature and humidity test chamber.

2. Working principle of constant temperature and humidity test chamber

1. The constant temperature and humidity test chamber consists of two parts: temperature regulation (heating, cooling) and humidification. Through the rotating fan installed on the top of the box, the air is discharged into the box to achieve gas circulation and balance the temperature and humidity in the box. The data collected by the temperature and humidity sensor built in the box are transmitted to the temperature and humidity controller (micro Information processor) performs editing and processing, and issues temperature and humidity adjustment instructions, which are completed through the joint efforts of the air heating unit, condensation tube, and heating and evaporation unit in the water tank.

2. The temperature of the equipment is adjusted through the temperature sensor built into the box, which collects data and is adjusted by the temperature controller (micro information processor). The air heating unit is connected to increase the temperature or the refrigeration solenoid valve is adjusted to reduce the temperature inside the box to achieve the desired temperature. Control the required temperature. The humidity adjustment of the equipment is achieved by collecting data through the built-in humidity sensor, adjusting it through the humidity controller (micro-information processor), connecting the water tank heating element, and increasing the humidity in the box by evaporating the water in the water tank or adjusting the refrigeration solenoid valve. Realize dehumidification to achieve the required humidity control.

3. The constant temperature and humidity test chamber is equipped with multiple protection measures; the temperature system is equipped with an over-temperature protector under the condition that the maximum safe allowable temperature can be set, and the air heating element can automatically cut off power when the rotating fan stops; the humidification system can be The water level in the humidification tank drops and the power supply is stopped; the refrigeration system also stops working as the temperature of the box increases (over 40°C) or the humidity increases.


 

Fulfill the standard

International Electrotechnical Commission standard, IEC68-2-03_Test method Ca_Steady-state damp heat

International Electrotechnical Commission Standard, IEC68-2-01_Test Method A_Cold

International Electrotechnical Commission Standard, IEC68-2-02_Test Method B_Dry Heat

U.S.  standard, MIL-STD-810F-507.4 Humidity

U.S. m standard, MIL-STD-810F-501.4 high temperature

U.S. m standard, MIL-STD-810F-502.4 low temperature

U.S. m standard, MIL-STD883C method 1004.2 Temperature and humidity combined cycle test

U.S. m standard, MIL-STD810D method 502.2

U.S. M Standard, MIL-STD810 Method 507.2 Procedure 3

Japanese Industrial Standard, JIS C60068-2-3-1987 Test Ca: moist heat, steady state

Japanese Industrial Standard,JIS C60068-2-2-1995 Test B: Dry heat

Japanese Industrial Standard, JIS C60068-2-1-1995 Test A: Low temperature

American semiconductor industry standard,JESD22-A101-B-2004 constant temperature and humidity test

American semiconductor industry standard,JESD22-A103-C-2004 high temperature storage test

American semiconductor industry standard,JESD22-A119-2004 low temperature storage test

Chinese National Standard, GB/T 2423.1-2001 Low Temperature

Chinese National Standard,GB/T 2423.2-2001 High Temperature

Chinese National Standard, GB/T 2423.3-1993 Constant Damp Heat Test Method

Chinese National Standard, GB2423.34-86 Temperature and Humidity Combined Cycle Test

Chinese national standard,GB/T2423.4-93 method

China National m Environmental Test Equipment Method, GJB150.9-8 Damp Heat Test
 

Product Parameters

 
Model HYH-80 HYH-150 HYH-225 HYH-408 HYH-800 HYH-1000
Inner Size(cm) 40*50 *40 50*60*50 50*75*60 60*85*80 100*100*80 100*100*100
Outer Size(cm) 60*159*137 70*167*150 70*172*160 80*176*171 120*195*175 148*195*175
Weight(kg) 160kg 220kg 300kg 550kg 960kg 1100kg
Temp.control method PID temperature humdity balance control
Temp.Range ModelA:0ºC ~150ºC     Model B:-20ºC ~150ºC;
Model C:-40ºC ~150ºC   Model D:-70ºC ~150ºC 
Humid.Range 20%~98%RH
Temp.Uniformity ±2ºC
Temp.Fluctuation ±0.5ºC
Humid.Uniformity ±3%R·H
Heating Rate ≥3ºC/min
Cooling Rate ≥1~1.5ºC/min
Cooling Method Air cooling
 

Detailed Photos

 

3370L Constant Temperature and Humidity Test Chamber Electrical Safety Tester Environmental Climatic Testing Equipment /Test Chamber
3370L Constant Temperature and Humidity Test Chamber Electrical Safety Tester Environmental Climatic Testing Equipment /Test Chamber
3370L Constant Temperature and Humidity Test Chamber Electrical Safety Tester Environmental Climatic Testing Equipment /Test Chamber
 

Company Information

3370L Constant Temperature and Humidity Test Chamber Electrical Safety Tester Environmental Climatic Testing Equipment /Test Chamber3370L Constant Temperature and Humidity Test Chamber Electrical Safety Tester Environmental Climatic Testing Equipment /Test Chamber3370L Constant Temperature and Humidity Test Chamber Electrical Safety Tester Environmental Climatic Testing Equipment /Test Chamber3370L Constant Temperature and Humidity Test Chamber Electrical Safety Tester Environmental Climatic Testing Equipment /Test Chamber3370L Constant Temperature and Humidity Test Chamber Electrical Safety Tester Environmental Climatic Testing Equipment /Test Chamber3370L Constant Temperature and Humidity Test Chamber Electrical Safety Tester Environmental Climatic Testing Equipment /Test Chamber3370L Constant Temperature and Humidity Test Chamber Electrical Safety Tester Environmental Climatic Testing Equipment /Test Chamber3370L Constant Temperature and Humidity Test Chamber Electrical Safety Tester Environmental Climatic Testing Equipment /Test Chamber

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
41