Constant Temperature and Humidity Pretreatment Chamber for Formaldehyde Detection Chamber

Product Details
Customization: Available
After-sales Service: 1 Year
Power Supply: AC 380V
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (22)
  • Constant Temperature and Humidity Pretreatment Chamber for Formaldehyde Detection Chamber
  • Constant Temperature and Humidity Pretreatment Chamber for Formaldehyde Detection Chamber
  • Constant Temperature and Humidity Pretreatment Chamber for Formaldehyde Detection Chamber
  • Constant Temperature and Humidity Pretreatment Chamber for Formaldehyde Detection Chamber
  • Constant Temperature and Humidity Pretreatment Chamber for Formaldehyde Detection Chamber
  • Constant Temperature and Humidity Pretreatment Chamber for Formaldehyde Detection Chamber
Find Similar Products
  • Overview
  • Product Description
  • Meet the standards
  • Company Information
Overview

Basic Info.

Model NO.
HY
Certification
CE, TUV, ISO
Warranty
1 Year
Volume Inside The Box (D*W*H)
2 Cabins (Can Be Customized)
Temperature Range Inside The Box
(15~30)°c (Temperature Deviation +1°c)
Power
Rated Power: 5kw, Operating Power: 3kw
Dimensions
W2100xd1100xh1800)mm
Static Leakage Rate
Under 1kpa Relative Pressure, Leakage Rate <0.2X10
Noise
65dB
Transport Package
Strong Wooden Case
Specification
Customized
Trademark
HUANYI
Origin
China
HS Code
8514199000
Production Capacity
10000pieces/Year

Product Description

Product Description

VOC Pretreatment Chamber

Pretreatment chamber can provide standard temperature and humidity VOC clean environment. After testing material temperature, humidity, pressure and VOC release balance, the pollutant release rate and release characteristics of materials and products can be tested.

Pretreatment principle:

The materials and products or their samples are placed in the pretreatment room, and the environmental conditions such as temperature, relative humidity, wind speed, pressure and indoor VOC cleaning conditions are adjusted to make the samples reach the same temperature and humidity in the balance room, and the release quantity and release rate of the samples reach the balance. At the same time, the cross-contamination of samples (the cross-contamination from TVOC and the cross-contamination of one-component voc) must be avoided.

 Usage: 

Plastic surface layer, VOC test in runway; 

Formaldehyde and VOC release test in wood products and building decoration materials; 

Research on pollutant release amount in materials; 

Environmental labeling product certification use.


 

Meet the standards

DIN EN 16516 WAS ADOPTED AS FORMALDEHYDE TESTING ON WOOD-BASED MATERIALS


ISO 16000-9:2006 Indoor air - Part 9: Determination of the emission of volatile organic compounds from building products and furnishing - Emission test chamber method

EN 717-1 Environmental box method for formaldehyde emission measurement of wood-based panels

ASTM D6007-02 Standard Test Method for Determining Formaldehyde Concentration in Wood

Products Released Gases by Small Scale Environment Chamber

ASTM D5116-06 Standard Guide For Small-Scale Environmental Chamber Determinations Of Organic

Emissions From Indoor Materials/Products

GB18580-2017 Formaldehyde emission limits in wood-based panels and their products for interior decoration

GB17657-2013 Experimental method for physical and chemical properties of wood-based panels and

veneered wood-based panels

 
Manufacturer HUANY INSTRUMENTS
Volume inside the box (D*W*H) 700mmx400mmx600mm 4 cabins (can be customized)
Temperature range inside the box (15~30)°C (temperature deviation +1°C)
Humidity range inside the box (30~80)%R.H. (Adjustment accuracy: +5%R.H)
Air replacement rate (0.2-2.0) times/hour (accuracy 0.05 times/H)
Air flow rate (0.1~1.0)Ms (continuously adjustable)
Background concentration control Formaldehyde concentration <0.1mg/m³
Power supply 220V 16A 50HZ
Power Rated power: 5KW, operating power: 3KW
Dimensions W2100xD1100xH1800)MM
Static leakage rate Under 1KPa relative pressure, leakage rate <0.2x10-3m3/min
Noise 65dB

Company Information

Constant Temperature and Humidity Pretreatment Chamber for Formaldehyde Detection ChamberConstant Temperature and Humidity Pretreatment Chamber for Formaldehyde Detection ChamberConstant Temperature and Humidity Pretreatment Chamber for Formaldehyde Detection ChamberConstant Temperature and Humidity Pretreatment Chamber for Formaldehyde Detection ChamberConstant Temperature and Humidity Pretreatment Chamber for Formaldehyde Detection ChamberConstant Temperature and Humidity Pretreatment Chamber for Formaldehyde Detection ChamberConstant Temperature and Humidity Pretreatment Chamber for Formaldehyde Detection ChamberConstant Temperature and Humidity Pretreatment Chamber for Formaldehyde Detection Chamber