The volume of the cabin is 60L ± 1L, and the number of cabins can be customized (2 cabins ~ 12 cabins).
2-box Type VOC & Formaldehyde test Chamber is suitable for volatile organic compound release sample equipment and is used to determine the volatile organic compound release.
Test for the release of harmful substances such as total volatile organic compounds (TVOC), benzene, toluene, xylene and ethylbenzene, carbon disulfide and formaldehyde.
2-box Type VOC & Formaldehyde test Chamber Purpose: VOC testing in plastic surfaces and runways; testing of formaldehyde VOC release in wood products and construction and decoration materials; research on the release of pollutants in materials; environmental labeling product certification purposes.
2-box Type VOC & Formaldehyde test Chamber Technical features: Multi-cabin combination structure, can test multiple samples at the same time; ultra-low VOC background concentration control, multi-layer physical and chemical filtration and purification; advanced air jacket temperature control technology, temperature and humidity adjustment technology, automatic temperature, humidity, pressure, and flow Records etc.
ASTM D6007-02 |
Standard Test Methods for Determination of Formaldehyde Concentration in air which are released from Wood Products with Small Scale Environmental Chamber |
ENV717-1 |
Environmental Chamber Method for Measurement of Formaldehyde Emission of Manmade Board |
EN13419-1 |
Determination of VOCs Release quantity of Building products Chapter One The Method for Releasing and Testing the Environmental Chamber |
ASTM D5116-17 |
Standard Guide for Determination of Organic Release from Interior Materials and Products with Small Scale Environmental Chamber |
ASTM D6330-14 |
Standard Operation for Determination of VOCs (Excluding Formaldehyde) Release from Wooden Board with Small Environmental Chamber under Specified Test Conditions |
ASTM D6670-18 |
Standard Operation for Determination of VOCs Release from Interior Materials and Products with Full Scale Environmental Chamber |
ASTM E1333-14 |
Standard Test Methods for Determination of Formaldehyde Concentration and Release Rate in Gases Released from Wood Products with Large Scale Environmental Chamber |
GB 18580-2017 |
Limits of Formaldehyde Release from Artificial Panel Machine Products of Interior Decoration Materials |
GB/T 31107-2014 |
General Technical Requirements for Climate Chambers for Testing Volatile Organic Compounds in Furniture |
Model: HYPV-60-2/HYPV-60-4/HYPV-60-6/HYPV-60-8
Effective volume of single cabin (L): 60L±1L
Number of working cabins: 2, 4, 6, 8
Internal dimensions: W300xD400xH500
Performance
temperature
Range: 15ºC~65ºC (optional 250ºC high temperature cleaning function)
Deviation: ≤±0.5ºC
Fluctuation: ≤±0.3ºC
Humidity
Range: 5%~80%RH
Deviation: ≤±3%RH
Fluctuation: ≤±2%RH
Air exchange rate: 0.2~2 times/hour
sealing rate
The climate chamber should meet one of the following sealing requirements:
a) At a positive pressure of 1Kpa (gauge pressure), the air leakage rate in the cabin is V.≤0.5%*cabin volume/min.
b) Cabin air leakage rate V.s5%*air supply rate Vs
Center wind speed: 0.1~0.3m/s (continuously adjustable)
Relative positive pressure: 10±5Pa
Recovery rate: formaldehyde, octanol, 4-phenylcyclohexene, dodecane, tetradecane recovery rate >80%
Background value: formaldehyde≤0.006mg/m, single VOC≤0.002mg/m3voc≤0.02mg/m3
Temperature control method: air jacket method (hot and cold counterbalance method)
Humidity control method: Dry air, moisture ratio two-way adjustment method
Material
Outer box: cold-rolled steel plate with 1.2mm surface electrostatic spraying, white
Inner box: SUS304 mirror stainless steel 1.0mm (8k mirror)
Insulation layer: high-density polyurethane foam + XPS (high temperature mineral wool)
Sealing material: silicone (medical grade) or polytetrafluoroethylene
Equipment operating environment: temperature: 5ºC~35ºC, humidity: ≤90%, no pollution sources around the cabin
Power supply: AC380 (1±10%)V (50±0.5)HZ three-phase four-wire + protective grounding
Installed capacity (kw): 3 3.8 5.3 6.5
Weight (kg): 230 350 480 510
Noise (dB): ≤s60dB
1.Q :How to provide after-sales service?
A:If customers need our engineers to come to the site for service, we will send out engineers to provide repair service for you.
2.Q: Can we visit and study in your factory?
A: Welcome to visit and study in our factory, we will show you our R&D and production capacity.
3.Q :Can I install and commission the calibration equipment on site?
A: Yes, we can send technicians and engineers to the customer's site for installation, commissioning and calibration.
4.Q: What are the transportation methods?
A :Air freight, sea freight, railroad transportation, all transportation methods according to the customer's needs.
5.Q : What are the packing methods?
A: Standard export wooden box packaging, solid and firm.
6.Q :How do you calibrate the equipment?
A: We have our own calibration and third-party calibration.
7.Q :What are the payment methods?
A :The payment methods are T/T, CIF, Paypal, L/C, VISA and so on.
8.Q :How long is the warranty period?
A :Warranty is 1 year, lifetime free service.
9.Q :What is the delivery time for your company's products?
A :This depends on the actual product you order, usually at least 30 days.