Technical Parameters
1. Studio size: 800*800*800mm/1000*1000*1000mm
2.External dimensions: W1270*H1630*D1050
3. Temperature range: rt+10ºC~60ºC (heating dust baking system);
4. Humidity range: ≤85%rh;
5. Dust concentration: 2~4kg/m3;
6. Dust specifications: Can dry talc powder pass through a square hole with a sieve hole of 75um and a wire diameter of 50um;
7. Vibration time: adjustable from 1s to 999h;
8. Dust blowing time: adjustable from 1s to 999h;
9. Dust dehumidification: electric heating dehumidification;
10. Equipped with a pumping and display measurement system for lower than air pressure testing;
11. Operation mode: program mode, fixed value mode;
12. Control system: embedded large-screen LCD touch screen
13. Safety protection: Automatically shut down and cut off the power supply in case of over-temperature or unexpected circumstances.
14. The powder circulation pump in the sealed test chamber can be replaced by other methods that can suspend the talc powder. Talcum powder should be filtered through a metal mesh sieve. The wire diameter is 50μm and the mesh size is 75μm. The dosage of talc powder is 2kg per cubic meter of test chamber volume, and the number of uses must not exceed 20 times. It should be possible to maintain uniform suspended dust of sufficient density in the test chamber.
15. When the tested shell is placed in the test chamber, the pressure inside the shell should be kept lower than the atmospheric pressure with a vacuum pump. The air pressure in the test chamber can also be changed to achieve periodic changes in the air pressure in the test chamber.
16. The instrument should have an emergency stop device to ensure safety when the test is abnormal.
17. The sealed test chamber cover (door) should be reliably sealed. It is recommended that the inner wall of the test chamber be made of conductive materials and be grounded to avoid static electricity accumulation.
18. There should be a dust recovery and treatment function after the test, and all operating functions of the equipment should meet the requirements of clause 13.4 in the standard gb4208-2008.
Equipment installation, testing and usage environment requirements:
1. The ambient temperature is +25ºC;
2. Relative humidity ≤85%;
3. Atmospheric pressure 80kpa ~ 106kpa;
Dust test box model | Workshop Dimension Deep X Width X Height(mm) |
HY-130 | 800X800X800 |
HY-131 | 800X1000X1000 |
HY-132 | 1000X1000X1000 |
HY-133 | 1000X1500.X1000 |
HY-134 | 1200X1800X1200 |
1.Q :How to provide after-sales service?
A:If customers need our engineers to come to the site for service, we will send out engineers to provide repair service for you.
2.Q: Can we visit and study in your factory?
A: Welcome to visit and study in our factory, we will show you our R&D and production capacity.
3.Q :Can I install and commission the calibration equipment on site?
A: Yes, we can send technicians and engineers to the customer's site for installation, commissioning and calibration.
4.Q: What are the transportation methods?
A :Air freight, sea freight, railroad transportation, all transportation methods according to the customer's needs.
5.Q : What are the packing methods?
A: Standard export wooden box packaging, solid and firm.
6.Q :How do you calibrate the equipment?
A: We have our own calibration and third-party calibration.
7.Q :What are the payment methods?
A :The payment methods are T/T, CIF, Paypal, L/C, VISA and so on.
8.Q :How long is the warranty period?
A :Warranty is 1 year, lifetime free service.
9.Q :What is the delivery time for your company's products?
A :This depends on the actual product you order, usually at least 30 days.