• Testing Equipment/Test Machine for Air Purifier Air Volume Device/Air Filter Test Machine/Cleanroom
  • Testing Equipment/Test Machine for Air Purifier Air Volume Device/Air Filter Test Machine/Cleanroom
  • Testing Equipment/Test Machine for Air Purifier Air Volume Device/Air Filter Test Machine/Cleanroom
  • Testing Equipment/Test Machine for Air Purifier Air Volume Device/Air Filter Test Machine/Cleanroom

Testing Equipment/Test Machine for Air Purifier Air Volume Device/Air Filter Test Machine/Cleanroom

After-sales Service: 1 Year
Power Supply: 380V
Certification: CE, TUV, ISO
Warranty: 1 Year
External Residual Pressure(PA)Range: 0~800
External Residual Pressure(PA) Accuracy: ±0.5%
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (21)
  • Overview
  • Product Description
  • Features
  • Meet the standards
  • Product Parameters
  • Company Profile
Overview

Basic Info.

Model NO.
HY
Air Volume(M3/H)
80~2000
Temperature(ºC)
20~30
Humidity(%Rh)
40~85
Transport Package
Standard Export Wooden Box
Specification
Customized
Trademark
HUANYI
Origin
China
HS Code
9024800000
Production Capacity
10000pieces/Year

Product Description

Product Description


Purpose and scope:
1 The use conditions, technical requirements, on-site inspection and test rules of the air volume measurement test device and the technical specifications of the main configuration instruments, meters and components
2 The air volume measurement test device is an air volume test device specially used for various types of range hoods, exhaust fans, air purifiers, etc. The measurement principle is the obstruction-type flow measurement principle, using a standard long-diameter low-speed nozzle as an obstruction, and measuring the air flow through the nozzle by measuring the static pressure difference between the two ends of the standard nozzle.
3 The measurement range of the air volume measurement test device is 80-2000 (m³/h).
4 The air volume measurement test device can be used for suction air volume test and exhaust air volume test.
 

Features


a. Device structure and appearance

1 )The overall structure is welded with steel plates, the outer welds are polished, and the inner and outer are sprayed with gray vertical grain paint.

2)After the nozzle, there are small doors on both sides, with observation windows on the doors, and manual box nozzle covers are used.

3) Using steel diagonal flow fan, automatic damping adjustment valve, the fan table can be separated, and can be installed at the suction end or exhaust end of the device for suction test or exhaust test.

4) The steel integral console is used, and the computer and all sensors are placed in the console.

5) The door sealing strip will not stick and deform under hot and humid conditions and can be replaced.

6) Appearance coating is smooth and smooth, with uniform color tone, no exposed bottom, no foaming, no layering.
 

b. Air volume system

1) Adopt automatic control, and can automatically draw the air volume - air pressure curve.

2) It can be connected to the computer system through the communication line extension, so that it has the test control database program, which can carry out the test report and data search and historical data curve drawing.


c. Safety and environmental protection

1) The protection terminals comply with the provisions of Article 7.1.7 of GB1497.

2) The device has protection and alarm functions such as overheating, power outage, and leakage.

Meet the standards

 
GB/T 1236-2000 Performance Test of Standardized Air Ducts for Industrial Ventilators
GB/T 2624.3-2006 Measurement of full-pipe fluid flow with differential pressure devices installed in pipes of circular cross-section - Part 3: Nozzles and Venturi nozzles

Product Parameters

 
 Index parameter
 
Range Accuracy
Control1) External residual pressure(Pa) 0~800 ±0.5%
Air volume(m3/h) 80~2000 ±1.5%2)
Note: 1) The static pressure (residual pressure) can be given to measure the air volume, and the residual pressure can also be measured given the air volume.
     2) ±1.5% of the actual measured value.

 
Measurement Temperature(ºC) 20~30 ±0.5
Humidity(%RH) 40~85 +2/-3
Atmospheric pressure(A.kPa) 80~1060 ±0.15%
Voltage(V) 0~240 ±0.5%
Current(A) 0~5 ±0.5%
Power(W) 0~1000 ±1.0%
Frequency(Hz) 50/60 ±0.5
Specimen speed(r/m) 0~2000 ±0.5%

Company Profile

Testing Equipment/Test Machine for Air Purifier Air Volume Device/Air Filter Test Machine/CleanroomTesting Equipment/Test Machine for Air Purifier Air Volume Device/Air Filter Test Machine/CleanroomTesting Equipment/Test Machine for Air Purifier Air Volume Device/Air Filter Test Machine/CleanroomTesting Equipment/Test Machine for Air Purifier Air Volume Device/Air Filter Test Machine/CleanroomTesting Equipment/Test Machine for Air Purifier Air Volume Device/Air Filter Test Machine/CleanroomTesting Equipment/Test Machine for Air Purifier Air Volume Device/Air Filter Test Machine/CleanroomTesting Equipment/Test Machine for Air Purifier Air Volume Device/Air Filter Test Machine/CleanroomTesting Equipment/Test Machine for Air Purifier Air Volume Device/Air Filter Test Machine/CleanroomTesting Equipment/Test Machine for Air Purifier Air Volume Device/Air Filter Test Machine/Cleanroom

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
41
Year of Establishment
2007-03-20