Customization: | Available |
---|---|
After-sales Service: | 1 Year |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
It is suitable for pressure pulse testing of automotive parts such as CO2 and air conditioning pipes.
Name | Project | Main technical parameters | |
Hydraulic control system | Medium system | Test medium | PAG oil (users need to provide) |
Medium temperature | -40~150ºC | ||
Heating rate | 0~3°ºC/min (average over the whole process, nonlinear), load 3KM heating power and thermal power | ||
Heating rate | 0~2ºC/min (average over the whole process, nonlinear), load 3KW heating power and thermal power | ||
Medium heating method | Closed indirect heating to avoid high temperature carbonization of the test medium | ||
Exhaust system | Independent automatic exhaust system | ||
Exhaust method | Side inlet and side outlet | ||
Electro-hydraulic servo pulse system | Pulse generator | Servo supercharger | |
Test product | C02 air conditioning pipe | ||
Test pressure | 0~17MPa | ||
Pulse frequency | 0~3Hz can be set arbitrarily (the larger the expansion volume, the smaller the pulse pressure range) | ||
Pulse time | Can be set arbitrarily | ||
Number of test paths | 2~10 channels | ||
Total expansion of the specimen | ≤250mL (the larger the frequency, the smaller the expansion volume requirement) | ||
Other | 1. The main oil tank and medium tank should be designed with a liquid level alarm. When the liquid level reaches the lower limit, the whole machine cannot be started. | ||
2. The main oil tank and medium tank have an over-temperature alarm and shutdown function. | |||
3. The test system is equipped with an exhaust device to effectively remove the gas in the test piece. | |||
High and low temperature environmental chamber | Ambient temperature control system | Temperature range | -40C~150ºC |
Temperature deviation | ±2ºC(no load) | ||
Heating rate (customizable) | 0~2ºC/min, with a certain mass load, linear or nonlinear temperature rise | ||
Cooling rate (customizable) | 0~2ºC/min, with a certain mass load, linear or nonlinear temperature rise | ||
Connection tooling | Side-in and side-out structure, aluminum profile frame, easy to adjust, connecting tooling can achieve horizontal and vertical adjustment; horizontal adjustment range (400-1400mm), vertical adjustment range (200-700mm) | ||
Safety door | Single door on the front, with coated heating and anti-frost hollow double-layer tempered glass observation window on the door; two fluororubber sealing strips and anti-condensation electric heating device on the door frame, with door limit and door opening stop function | ||
Lighting | Safety door observation window is equipped with lighting | ||
Computer control system | 1. Waveform control: Using FPID electro-hydraulic control technology, the pulse pressure waveform, pulse number, static pressure time, medium temperature, and pulse frequency can be set arbitrarily within the controllable range, and the pressure measurement accuracy can be improved. 2. Pulse waveform: trapezoidal wave, sine wave, triangle wave 3. Others (1) It has the functions of oil temperature over-high, pressure over-high, leakage sound and light alarm, and emergency shutdown (2) The alarm point can be set for test piece leakage. When the leakage reaches a certain level, the system will automatically alarm and stop working (3) The test system should provide corresponding equipment calibration conditions (such as pressure sensor calibration interface or calibration procedure) |
||
PC | Lower computer | PLC+NI card | |
Upper computer | Touch screen computer | ||
Software | Control software | Pulse control software (developed by LabVIEW) | |
Report format | Microsoft Office |
1.Q :How to provide after-sales service?
A:If customers need our engineers to come to the site for service, we will send out engineers to provide repair service for you.
2.Q: Can we visit and study in your factory?
A: Welcome to visit and study in our factory, we will show you our R&D and production capacity.
3.Q :Can I install and commission the calibration equipment on site?
A: Yes, we can send technicians and engineers to the customer's site for installation, commissioning and calibration.
4.Q: What are the transportation methods?
A :Air freight, sea freight, railroad transportation, all transportation methods according to the customer's needs.
5.Q : What are the packing methods?
A: Standard export wooden box packaging, solid and firm.
6.Q :How do you calibrate the equipment?
A: We have our own calibration and third-party calibration.
7.Q :What are the payment methods?
A :The payment methods are T/T, CIF, Paypal, L/C, VISA and so on.
8.Q :How long is the warranty period?
A :Warranty is 1 year, lifetime free service.
9.Q :What is the delivery time for your company's products?