Principle of environmental chamber for bag method VOC detection
| Model | HYVD-48 | HYVD-24 | |
| Internal volume(m³) | 48 | 24 | |
| Internal dimension | W | 6000 | 3000 |
| D | 4000 | 4000 | |
| H | 2000 | 2000 | |
| Performance | Temperature | Range | 15ºC~85ºC |
| Volatilitty | ≤±0.5ºC | ||
| Deviation | ≤±2ºC | ||
| Background value(mg/m³) | Formaldehyde: ≤0.02mg/m³; Acetaldehyde: ≤0.01mg/m³; Touluene: ≤0.02mg/m³ Ethlbenzene: ≤0.02mg/m³; Xylene ≤0.02mg/m³; Styrene≤0.002mg/m³; TVOC≤300μg/m³; Single VOC ≤20μg/m³ |
||
| Relative positive pressure | 10±5Pa | ||
| Air velocity | 0.1~1.0m/s(continuously adjustable) | ||
| Air exchange volume measurement | Electronic flowmeter | ||
| Temperature control method | Electric heating, SCR load regulation module, forced hot air circulation | ||
| Observation window | 330*450mm(W*H) , two | ||
| Material | Outer chamber | Cold rolled steel sheet 0.8mm, surface eletrostatic spraying , white | |
| Inner chamber | SUS304 mirror stainless steel 1.2mm | ||
| Insulation | High temperature resistant material+polyrethane composite, thickness 100mm | ||
| Sealing material | Sillicone (medical grade) or polytetrafluoroethylene | ||
| Power supply | Three-phase five-wire+protective grounding | ||
| Installed capacity(kw) | 35 | 23.5 | |
| Noise(dB) | ≤65dB | ||
| Ambient temperature | 5ºC~35ºC | ||