Thermal Shock Test Chamber with Two Zones
| Customization: | Available |
|---|---|
| After-sales Service: | 1 Year |
| Power Supply: | 220V/380V |
360° Virtual Tour
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
Find Similar Products
Basic Info.
- Model NO.
- HY
- Certification
- CE, TUV, ISO
- Warranty
- 1 Year
- Hot Exposure Range
- +50 ℃ to 200℃
- Cold Exposure Range
- +20℃ to -80℃
- Pre-Heat Limit
- +200℃
- Pre-Cool Limit
- -80℃
- Temperature Fluctuation
- ±0.5℃
- Temperature Deviation
- ≤±2.0°c
- Heat-up Time
- Rt to 180℃≤20min
- Ambient Temp.Range
- Rt to 35℃
- Transport Package
- Wooden Packing
- Specification
- Customized
- Trademark
- HUANYI
- Origin
- China
- HS Code
- 8514199000
- Production Capacity
- 10000pieces/Year
Product Description
Thermal shock test chamber (two-chamber temperature shock test chamber) can simulate the environment of instantaneous changes in high and low temperatures.
Two-box Type Thermal Shock Test Chamber used to determine whether a device will suffer physical damage or performance degradation when exposed to rapid changes in ambient atmospheric temperature.
The two-box thermal shock test chamber is a necessary testing equipment in the fields of aviation, automobiles, home appliances, scientific research and other fields.
It evaluates and measures the parameters and performance of testing instruments, machinery, electrical, electronic products and components after high and low temperature impact tests.
Two-box Type Thermal Shock Test Chamber the two-chamber method high and low temperature impact test chamber is equipped with two working rooms, namely high temperature zone and low temperature zone. time
The specimen is moved to the corresponding working room through a hanging basket for high and low temperature impact testing.
Liquid-to-liquid thermal shock test chambers are available in small and large capacities to meet different testing requirements. Samples are automatically transferred from the cold chamber to the hot chamber via baskets. The basket slides smoothly vertically through guide rails, exposing the sample to both chambers. Thermal shock testing is widely used in metals, plastics, rubber, electronics and other materials, and can be used as an important reference for improving product quality.
MIL-STD-810F Method 504.4 Temperature Shock
EIA-364-32 Thermal Shock Test Procedure for Electrical Connectors and Receptacles,
MIL-DTL-38999 Testing, Section 4.5.3 Thermal Shock,
TIA/EIA-455-71 Procedure for measuring the effects of temperature shock on fiber optic components
| Model | HYTW-105 | HYTW-300 | HYTW-497 |
| Interior(cm) (WxDxH) | 48x48x46 | 68x68x65 | 90x85x65 |
| external(cm) (WxDxH) | 108x195x155 | 128x260x195 | 154x264x195 |
| Basket dimension | 38x35x38 | 52x52x55 | 60x60x50 |
| Specimen basket load capacity | 5kg(alumimum) | 15kg(alumimum) | 10kg(alumimum) |
| Test temperature range | -40ºC to +150ºC optional -70ºC/-80ºC to +150ºC/+180ºC | ||
| Hot exposure range | +50 ºC to 200ºC | ||
| Cold exposure range | +20ºC to -80ºC | ||
| Pre-heat limit | +200ºC | ||
| Pre-cool limit | -80ºC | ||
| Temperature fluctuation | ±0.5ºC | ||
| Temperature deviation | ≤±2.0°C | ||
| Heat-up time | RT to 180ºC≤20min | ||
| Pull-down time | RT to -65ºC ≤55 min. | ||
| Temp.recovery time | Within 5 min. | ||
| Transfer time | Between hot and cold chamber within 10seconds | ||
| Specimen baskets | Shelf brakets on two levels of fixed location | ||
| Refrigeration system | Mechanical cascade refrigeration system | ||
| Compressor | Germany / | ||
| refrigerant | Honeywell R404A &R23 | ||
| condenser | Air-cooled, cold accumulator | ||
| Ambient temp.range | RT to 35ºC | ||
| Power supply | AC 380V @50Hz three phases | ||
| Cooling method | Optional air-cooled or water cooled, depends on specimen and inner size | ||
| Cooling tower | Water cooled model type is requested. | ||









1.Q :How to provide after-sales service?
A:If customers need our engineers to come to the site for service, we will send out engineers to provide repair service for you.
2.Q: Can we visit and study in your factory?
A: Welcome to visit and study in our factory, we will show you our R&D and production capacity.
3.Q :Can I install and commission the calibration equipment on site?
A: Yes, we can send technicians and engineers to the customer's site for installation, commissioning and calibration.
4.Q: What are the transportation methods?
A :Air freight, sea freight, railroad transportation, all transportation methods according to the customer's needs.
5.Q : What are the packing methods?
A: Standard export wooden box packaging, solid and firm.
6.Q :How do you calibrate the equipment?
A: We have our own calibration and third-party calibration.
7.Q :What are the payment methods?
A :The payment methods are T/T, CIF, Paypal, L/C, VISA and so on.
8.Q :How long is the warranty period?
A :Warranty is 1 year, lifetime free service.
9.Q :What is the delivery time for your company's products?
A :This depends on the actual product you order, usually at least 30 days.