• Temperature Humidity Calibration Chamber for Testing Thermometer & Hygrometer
  • Temperature Humidity Calibration Chamber for Testing Thermometer & Hygrometer
  • Temperature Humidity Calibration Chamber for Testing Thermometer & Hygrometer
  • Temperature Humidity Calibration Chamber for Testing Thermometer & Hygrometer
  • Temperature Humidity Calibration Chamber for Testing Thermometer & Hygrometer
  • Temperature Humidity Calibration Chamber for Testing Thermometer & Hygrometer

Temperature Humidity Calibration Chamber for Testing Thermometer & Hygrometer

After-sales Service: 1 Year
Power Supply: AC 380V
Certification: CE, TUV, ISO
Warranty: 1 Year
Control Method: 7-Inch LCD High-Definition Display Touch Screen
Temperature Change Rate: ≤0.1ºC/Min (Under Controlled Steady State)
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (21)
  • Overview
  • Product Description
  • Features
  • Product Parameters
  • Company Information
Overview

Basic Info.

Model NO.
HYBD-1000
Humidity Fluctuation
Better Than ±0.8% Rh (at 20ºC)
Humidity Change Rate
≤0.4%Rh/Min (Under Controlled Steady State)
Humidity Uniformity
Better Than 1%Rh (15ºC, 20ºC, 30ºC
Transport Package
Standard Export Wooden Box
Specification
Customized
Trademark
HUANYI
Origin
China
HS Code
9013809000
Production Capacity
10000pieces/Year

Product Description

Product Description

Calibration of temperature and humidity sensors determines the sensor error by comparing it to a reference standard of known accuracy. The main purpose of calibration is to adjust the output value of the sensor to make it consistent with the temperature and humidity values in the real environment. In the calibration process of temperature and humidity sensors, relevant temperature and humidity sensor calibration equipment will be used. Next, let's take a look at how the temperature and humidity sensors are calibrated.

Basic principle: Use one or more standard reference sensors to measure values under known temperature and humidity conditions and compare them with the output of the sensor to be calibrated. Based on the comparison results, the deviation of the sensor to be calibrated can be calculated and adjusted accordingly.


Calibration steps:
1. Determine the calibration equipment and select a highly accurate and reliable reference sensor as the calibration equipment.
2. Prepare standard conditions to create a stable environment and determine standard conditions with known temperature and humidity values.
3. Perform a calibration test. Place the sensor to be calibrated and the reference sensor under standard conditions and record their output values.
4. Comparison and calculation: Compare the output value of the sensor to be calibrated with the output value of the reference sensor, and calculate the calibration deviation.
5. Adjustment and verification According to the calibration deviation, adjust the sensor to be calibrated, and perform the calibration test again to verify the calibration effect.

Features


1. Humidity can be controlled over wide temperature area;
2. Excellent characteristics of humidity control;
3. Special temperature and humidity controller;
4. Automatic/manual defrosting;
5. Powerful environmental adaptability;
6. Powerful human interface;
7. Supporting PANRAN Smart Metrology APP.

Product Parameters

 
Performance Temperature range -30ºC~60ºC
Humidity range 5%RH~95%RH
Resolution 0.01ºC;0.01%RH
Temperature fluctuation ≤±0.05ºC/30min(full range)
Humidity fluctuation ≤0.4%RH
Temperature uniformity 0.2ºC ≤0.4%RH
Humidity uniformity ≤0.6%RH(20ºC)
Control sensor Temperature and humidity probe
Touch screen 7 inch screen
Power supply AC 220V 50HZ
Power (KW) 4.5
 

Company Information

Temperature Humidity Calibration Chamber for Testing Thermometer & HygrometerTemperature Humidity Calibration Chamber for Testing Thermometer & HygrometerTemperature Humidity Calibration Chamber for Testing Thermometer & HygrometerTemperature Humidity Calibration Chamber for Testing Thermometer & HygrometerTemperature Humidity Calibration Chamber for Testing Thermometer & HygrometerTemperature Humidity Calibration Chamber for Testing Thermometer & HygrometerTemperature Humidity Calibration Chamber for Testing Thermometer & HygrometerTemperature Humidity Calibration Chamber for Testing Thermometer & HygrometerTemperature Humidity Calibration Chamber for Testing Thermometer & Hygrometer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now