Rotary Centrifuge used to determine the force (except gravity) generated by electronic components, small equipment and other electronic products subjected to steady-state acceleration (constant acceleration) environments, such as those produced by vehicles, aerial vehicles, rotating machinery and projectiles. The adaptability and performance of the structure is good, the structural integrity of some components is evaluated, and the electrical parameters of the test sample can be evaluated under the steady acceleration environment.
Rotary centrifuge/Swing Type Centrifuge/Centrifuge Acceleration Test Machine also called a linear acceleration test systems. The system consists in two parts one Mechanical body with motor arrangement coupled with rotating arm and second electronics control panel Speed control unit. A AC/DC Motor is used to rotate the platform mounted on the rotating shaft. Set of current rating slip rings are provided to feed the electrical signal to the specimen under dynamic test condition. System is safe from all protections like Over load, field fail, Door interlock etc.
The system should be installed on a floor. Machine should be positioned such that there is ample clearance for opening doors and for removal of panels and covers from all sides. Controls should be easily accessible and visible for the operator and still allow adequate working room to perform fixturing and testing.
1. Real-time computer control, automatic generation of experimental reports;
2. Real-time display of test curves and tolerances, test time;
3. Multi-stage accelerated test can be realized;
4. It can realize open circuit, over limit and over speed protection;
5. Can realize automatic and manual control;
6. The number and size of the current collecting slip ring circuit can meet any test requirements.
Meet the standard
GB/T2423
GJB150
GJB360
MILST810F
MISTD202F
IEC68-2-7
MIL-STD-883C
Model |
HYZP-3 |
HYZP-5 |
HYZP-10 |
HYZP-20 |
HYZP-005 |
HYZP-004 |
HYZP-003 |
Maximum load (kg) |
3 |
5 |
10 |
20 |
0.05 |
0.04 |
0.03 |
Total load (kg) |
15 |
20 |
20 |
40 |
0.5 |
0.4 |
0.3 |
Acceleration m/s2 |
300-2000 |
30-2000 |
50-1000 |
50-1000 |
5000-200000 |
5000-400000 |
5000-800000 |
Sample allowable height (mm) |
200 |
200 |
300 |
300 |
Test article direction |
X, Y, and Z directions are respectively performed |
X, Y, Z coordinates in six directions |
The test center calculates the installation radius (mm) on the turntable |
200 |
200 |
750 |
750 |
100 |
80~100 |
Start time (min) |
≤3 |
≤4 |
≤3 |
≤3 |
≤4 |
≤5 |
≤5 |
Continuous working time (min) |
60 |
60 |
60 |
60 |
30 |
5 |
5 |
Power supply and power consumption |
AC 380V 1.5KVA |
AC 380V 5KVA |
AC380V 4KVA |
AC380V 6.5KVA |
Dimensions (L*W*H)mm |
924*910*1242 |
1953*470*993 |
800*800*830 |
Electrical device |
15 ring 500V 5A |
12 ring 500V 5A |
Weight (kg) |
1500 |
1700 |
2300 |
2500 |
1500 |
100 |
Control System |
Industrial computer system |
Fulfil requirements |
GB/T2423 GJB150 GJB360 MIL-STD-810F MIL-STD-202F IEC68-2-7 MIL-STD-883C |
Remarks |
The power-on device and control accuracy can be configured according to relevant standards or user requirements. |