• Compound Salt Spray Chamber Environment Test Chamber
  • Compound Salt Spray Chamber Environment Test Chamber
  • Compound Salt Spray Chamber Environment Test Chamber
  • Compound Salt Spray Chamber Environment Test Chamber
  • Compound Salt Spray Chamber Environment Test Chamber
  • Compound Salt Spray Chamber Environment Test Chamber

Compound Salt Spray Chamber Environment Test Chamber

After-sales Service: 1 Year
Power Supply: AC
Certification: CE, TUV, ISO
Warranty: 1 Year
Maximum Power: 13kw
Working Noise: ≤ 70dB
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (21)
  • Overview
  • Product Description
  • Application
  • Product Parameters
  • Company Information
Overview

Basic Info.

Model NO.
HY-SSP-10
Maximum Current
60A
Temperature Range
Rt ~ 60 ºC
Humidity Range
20 ~ 98% R.H
Temperature Resolution
0.01ºC
Humidity Resolution
0.1%R.H
Transport Package
Strong Wooden Case
Specification
Customized
Trademark
HUANYI
Origin
China
HS Code
9013809000
Production Capacity
10000pieces/Year

Product Description

Product Description

Compound salt spray test chamber
The equipment has temperature, humidity and heat alternating salt fog compound testing machine that have  the function of temperature and humidity regulation.Used for testing various performance indexes and quality management of accessories under alternating conditions of high temperature, humid heat, drying and salt spray. 

The corrosion of metal materials mostly occurs in the atmosphere, which contains corrosive components and corrosive factors such as oxygen, humidity, temperature changes, pollutants, and so on. The corrosion of salt spray to metal salts is mainly caused by the electrochemical reaction of conductive salt solutions entering the metal, forming a micro-battery system of "low potential metal electrolyte solution - high potential impurities", electron transfer occurs, and the metal dissolves as an anode.

The main function of the compound salt spray corrosion process is chloride ions. It has a strong penetrating force, which easily penetrates the metal oxide layer into the metal and destroys the passivation state of the metal. At the same time, chloride has less hydration energy. It easily adsorbs on metal surfaces and replaces oxygen in the oxide layer that protects the metal from destroying the metal.

The programmable compound salt spray test chamber not only has the function of a basic compound salt spray test chamber but also combines the function of alternating cycle salt spray testing to provide test environments such as obsessive corrosion and filamentous corrosion. Test environments such as hot air drying, damp heat, and forced drying.

The compound salt spray test chamber is mainly used for auto parts, aviation equipment, photographic devices, building materials, electroformed coatings, electronic motor systems, and other metals under harsh environmental changes in electrochemical corrosion resistance.

Application

Function of the compound salt spray test chamber
Although it is called the Salt Spray Test and the Salt Spray Test Chamber, the name is somewhat misleading. Sprays usually come in the form of fog or ultra-fine mist, creating an environment that accelerates corrosion. This situation can also be isolated by controlling the ambient temperature at 95°F (35°C) and PH.

Salt spray testing is used to determine the corrosion resistance of a material. These typically include the following:

Phosphating the surface followed by paint, primer, varnish, or anti-rust treatment
Galvanized and zinc alloys
Electroplated chrome, nickel, copper, and tin
Coatings that are not electrolyzed, such as zinc sheet coatings
Organic coatings
Paints and coatings

Product Parameters

 

Working noise ≤ 70db 1 m from the front of the machine and 1.2 m from the ground to measure
Maximum power 13KW
Maximum current 60A
Power supply conditions and power supply AC380V three-phase four-wire + protection grounding
Allowable voltage fluctuation range: ±10%V
Allowable fluctuation range of frequency: (50±0.5) HZ
TN-S way power supply or TT way power supply, protection ground resistance less than 4Ω, the user is required to configure the corresponding capacity of the air or power switch for the equipment at the installation site, and this switch must independently control the use of this equipment
The use of environmental conditions A, the ambient temperature of 5 ~ 30 ºC, relative humidity ≤ 85% R.H;
B. The installation site must be flat and vibration-free ground;
C. The equipment must be away from heat sources and flammable and explosive substances;
D. The installation location should not be exposed to direct sunlight and maintain indoor air circulation;
E. The installation site must be clean, not installed in dusty places or dust exhaust ports, etc.
Temperature and humidity range Temperature range: RT ~ 60 ºC
Humidity range: 20 ~ 98% R.H
Control accuracy Temperature resolution 0.01ºC
Humidity resolution 0.1%R.H
Temperature deviation ±1.0ºC
Humidity deviation ±2%R.H
Temperature uniformity ±2ºC
Humidity uniformity
 
±3%RH(when humidity>50%RH) ±5%RH(when humidity≤50%RH)
Temperature fluctuation ±0.5ºC
Humidity fluctuation ±2%R.H
Test conditions Laboratory temperature RT ~ 60 ºC can be set arbitrarily (salt spray corrosion test 35 ºC ± 1 ºC / 50 ºC ± 1 ºC)
Pressure barrel temperature 47 ºC ± 1 ºC / 63 ºC ± 1 ºC
Spray volume 1.0 ~ 2.0 m1/80cm2h (at least 16 hours of collection, take its average)
Relative humidity 20% ~ 98% R.H
Brine concentration 5% or concentration of 5% plus 0.26 grams of copper chloride (CuCl2 2H2O)
Spray pressure 1.00 ± 0.01kgf/cm2
Acid-base value PH Neutral test 6.5 ~ 7.2 acid test 3.0 ~ 3.3
Specimen plate installation angle 15°~30°

Company Information

Compound Salt Spray Chamber Environment Test ChamberCompound Salt Spray Chamber Environment Test ChamberCompound Salt Spray Chamber Environment Test ChamberCompound Salt Spray Chamber Environment Test ChamberCompound Salt Spray Chamber Environment Test ChamberCompound Salt Spray Chamber Environment Test ChamberCompound Salt Spray Chamber Environment Test ChamberCompound Salt Spray Chamber Environment Test Chamber

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
41
Year of Establishment
2007-03-20