• Temperature Humidity Vibration Integrated Test Chamber / Temperature and Humidity Controls for Automotive
  • Temperature Humidity Vibration Integrated Test Chamber / Temperature and Humidity Controls for Automotive
  • Temperature Humidity Vibration Integrated Test Chamber / Temperature and Humidity Controls for Automotive
  • Temperature Humidity Vibration Integrated Test Chamber / Temperature and Humidity Controls for Automotive
  • Temperature Humidity Vibration Integrated Test Chamber / Temperature and Humidity Controls for Automotive
  • Temperature Humidity Vibration Integrated Test Chamber / Temperature and Humidity Controls for Automotive

Temperature Humidity Vibration Integrated Test Chamber / Temperature and Humidity Controls for Automotive

After-sales Service: 1 Year
Power Supply: AC 220V
Certification: CE, TUV, ISO
Warranty: 1 Year
Temperature Range: -40°c~+60°c
Temperature Control Accuracy: ≤±1°ºC
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (21)
  • Overview
  • Product Description
  • Features
  • Meet the standards
  • Product Parameters
  • Company Profile
Overview

Basic Info.

Model NO.
HY
Humidity Range
20~95%Rh
Humidity Control Accuracy
≤±3%Rh
Irradiation Distance
1.5m-2.5m
Transport Package
Standard Export Wooden Box
Specification
Customized
Trademark
HUANYI
Origin
China
HS Code
8514199000
Production Capacity
10000pieces/Year

Product Description

Product Description

The vehicle high and low temperature environment test chamber specializes in providing vehicle high and low temperature testing services. It complies with relevant international and domestic standards and can evaluate the tolerance, reliability and adaptability of the vehicle or interior parts in extreme temperature environments to ensure vehicle quality. and stable performance, improving user satisfaction and trust. HUANYI Instruments is committed to providing the automotive industry with safe, stable, and energy-saving comprehensive vehicle testing solutions, and continues to help the automotive industry product R&D and reliability upgrades.

Application areas

The vehicle environment model laboratory, also known as the vehicle environment test chamber, can reproduce natural conditions, simulate environmental temperature and humidity, sunshine intensity, rain corrosion, driving road conditions, exhaust emissions and fresh air supply, etc., and perform functions such as vehicle development and performance evaluation. and quality inspection are of great significance. This system can be used to complete engine cooling tests, air conditioning system development, hot and cold emission tests, heating system development, hot and cold start tests, defrosting and defrosting tests, etc., which can improve the comfort, safety and reliability of automobiles and accessories. Continuously improve to provide an effective platform.

Features


1. Adopt advanced cold end balance control and PID automatic adjustment technology to achieve energy saving of more than 30% at high and low temperatures and constant temperature.

2. The compressors and accessories of the refrigeration system are all made of internationally renowned brands with long-lasting and reliable operation, excellent workmanship, low failure rate, and environmentally friendly refrigerants, which comply with the requirements of international environmental protection conventions.

Meet the standards

GB/T10589-2008 Low temperature test chamber technical conditions
GB/T2423.3-2008 (1EC68-2-3) Test Ca: Constant damp heat test method
GJB150.9A-2009 Damp heat test method
GB/T2423.4-2008/IEC6008-2-30:2005 Test Db: Alternating moist heat method
GB/T2424.6-2006 Electrical and electronic products environmental testing temperature and humidity test chamber performance confirmation
GB/T2424.7-2006 Electrical and electronic products environmental testing test A and B (with load) temperature test chamber measurement
GB/T5170.2-2008 Temperature test equipment requirements
GB/T5170.5-2008 Humidity and Heat Test Equipment Requirements
GB/T5170.18-2005 Basic parameter verification method for environmental testing equipment for electrical and electronic products Temperature/humidity combined cycle testing equipment
GB/T10586-2006 Technical Conditions of Humid Heat Test Chamber

Product Parameters

 
Inner box size (WxHxD) cm 400X300X700
Temperature range -40~+80°C
Temperature change rate 25°C←→-40°C, 2.5 hours (no load, average over the entire process) 25°C←→60°C 2 hours (no load, average over the entire process)
Temperature control accuracy ±1°C (measured at the control point, when there is no heat load change)/±1.2°C (measured at the control point, when conducting an emission test)
Temperature and humidity deviation ±2°C (without heat load change)/+3.0%RH (>75%RH) ±5.0%RH (<75%RH)
Humidity range 10%~95%RH
Humidity uniformity ±3.0%RH (no load)
Humidity fluctuation ±2.0%RH
Fresh air system When the ambient temperature is 0ºC~-40ºC, the air volume is greater than 700m?h. When the ambient temperature is 20ºC, the air volume is greater than 2500m'/h. The fresh air blower is a variable frequency motor, and the fresh air unit has a manual switch and Air volume adjustment function.
Automobile exhaust emission system Provide stainless steel variable frequency fans, pipelines from the cabin to the outdoors and exhaust back pressure control devices so that the static pressure at the outlet of the exhaust pipe during the entire test does not exceed ±1.25 kPa (meeting GB18352.2-2001); the maximum Exhaust air extraction volume, 4000m'/h.
Air conditioning system  
Refrigeration method Vapor compression refrigeration
Circulation fan Vapor compression refrigeration
The whole frame Circulating air flow is approximately 150.000 mi/h
Floor construction The overall environmental test chamber has a three-dimensional layout of upper and lower floors. The lower floor is the environmental cabin and the upper floor is the circulating air duct. The design structure is basically the same as the wall. In addition, an anti-slip layer and a pressure plate are added.
Anti-slip stainless steel thickness >3mm
Fulfill the standard 70/220/EEC, 715/2007/EC and 692/2008/ECEPA Tirel, NLEV and Tire2GB 18352.2, GB18352.3, HJ/T400-2007 and HJ/T390-2007, National 5 regulations
Remark Different vehicle sizes can be customized according to needs

Company Profile

Temperature Humidity Vibration Integrated Test Chamber / Temperature and Humidity Controls for AutomotiveTemperature Humidity Vibration Integrated Test Chamber / Temperature and Humidity Controls for AutomotiveTemperature Humidity Vibration Integrated Test Chamber / Temperature and Humidity Controls for AutomotiveTemperature Humidity Vibration Integrated Test Chamber / Temperature and Humidity Controls for AutomotiveTemperature Humidity Vibration Integrated Test Chamber / Temperature and Humidity Controls for AutomotiveTemperature Humidity Vibration Integrated Test Chamber / Temperature and Humidity Controls for AutomotiveTemperature Humidity Vibration Integrated Test Chamber / Temperature and Humidity Controls for AutomotiveTemperature Humidity Vibration Integrated Test Chamber / Temperature and Humidity Controls for AutomotiveTemperature Humidity Vibration Integrated Test Chamber / Temperature and Humidity Controls for Automotive

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
41
Year of Establishment
2007-03-20